1. Product Details

  2. Variations

  3. Variations

  4. Literature

Detailed Description

The compact CR 030 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures.

  • Compact design
  • Built-in overheat protection
  • Integrated adjustable thermostat or fixed hygrostat
  • Double insulated plastic housing

Technical Data
Heating element: high performance cartridge
Overheat Protection: with automatic reset and second-tier one shot fuse
Heating Body: extruded aluminum
Axial fan, ball bearing: service life 50,000 h at +77°F (25°C)
Air flow, free blowing: 94 cfm (160 m³/h)
Connection: 2-pole terminal AWG 16 max. (1.5 mm²) with strain relief, clamping torque 0.8 Nm max.
Housing: plastic, UL 94V-0, black
Mounting: M5 screws (not included)
Mounting position: vertical airflow (air outlet up)
Operating¹ / Storage temperature: -49 to +158°F (-45 to +70°C)
Operating / Storage humidity: max. 90% RH (non-condensing)
Dimensions: 3.9 x 5.7 x 6.6” (100 x 145 x 168 mm)
Weight: approx. 3.1 lbs. (1.4 kg)
Protection class / type: II (double insulated) / IP20
¹Operating temperature of heater with integrated hygrostat: +32 to +140°F (0 to +60°C)

Variations

  1. CR 030: 03051.0-00

    Heating capacity: 950 W
    Operating voltage: 230 VAC 50/60 Hz
    Recommended pre-fuse T (time-delay): 6.3 A
    Setting range²: 0 to 60°C
    Approvals: UL File No. E234324 / VDE / EAC
    ² Switching difference 12.6°F ± 7°F tolerance (7 K ± 4 K)

  2. CR 030: 03051.0-02

    Heating capacity: 950 W
    Operating voltage: 230 VAC 50/60 Hz
    Recommended pre-fuse T (time-delay): 6.3 A
    Setting range²: 65% RH, factory-set
    Approvals: UL File No. E234324 / VDE / EAC
    ² Switching difference 12.6°F ± 7°F tolerance (7 K ± 4 K)

  3. CR 030: 03051.0-07

    Heating capacity: 950 W
    Operating voltage: 230 VAC 50/60 Hz
    Recommended pre-fuse T (time-delay): 6.3 A
    Setting range²: none (no integrated controls)
    Approvals: UL File No. E234324 / VDE / EAC
    ² Switching difference 12.6°F ± 7°F tolerance (7 K ± 4 K)

  4. CR 030: 03059.9-00

    Heating capacity: 950 W
    Operating voltage: 120 VAC 50/60 Hz
    Recommended pre-fuse T (time-delay): 10.0 A
    Setting range²: 32 to 140°F
    Approvals: UL File No. E234324 / EAC
    ² Switching difference 12.6°F ± 7°F tolerance (7 K ± 4 K)

  5. CR 030: 03059.9-02

    Heating capacity: 950 W
    Operating voltage: 120 VAC 50/60 Hz
    Recommended pre-fuse T (time-delay): 10.0 A
    Setting range²: none (no integrated controls)
    Approvals: UL File No. E234324 / EAC
    ² Switching difference 12.6°F ± 7°F tolerance (7 K ± 4 K)