1. Product Details

  2. Variations

  3. Variations

  4. Literature

Detailed Description

The compact CS 030 high performance fan heater prevents formation of condensation and provides an evenly distributed interior air temperature in enclosures.

Features

  • Compact design
  • Built-in overheat protection
  • Integrated adjustable thermostat (optional)
  • Double insulated plastic housing

Technical Data
Heating element: PTC resistor – temperature limiting
Overheat Protection: built-in temperature limiter
Axial fan, ball bearing: service life 50,000 h at +77 °F (25 °C)
Air flow, free blowing: 94 cfm (160 m³/h)
Connection: 2-pole terminal AWG 16 max. (1.5 mm²) with strain relief, clamping torque 0.8 Nm max
Housing: plastic, UL 94V-0, black
Mounting: M5 screws (not included)
Mounting position: vertical airflow (air outlet up)
Operating / Storage temperature: -49 to +158 °F (-45 to +70 °C)
Operating / Storage humidity: max. 90% RH (non-condensing)
Dimensions: 4.7 x 5.7 x 6.6” (120 x 145 x 168 mm)
Weight: approx. 2.6 lbs. (1.2 kg)
Protection class / type: IP20 / II (double insulated)
Heating capacity¹: 1,200 W
¹at 68 °F (20 °C) ambient temperature

Variations

  1. CS 030: 03060.0-00

    Operating voltage: 230 VAC 50/60 Hz
    Max. current (inrush): 13.0 A
    Recommended pre-fuse T (time-delay): 10.0 A
    Setting range²: 0 to 60 °C
    Approvals: UL File No. E150057³ / VDE / EAC
    ²Switching difference 12.6°F ± 7°F tolerance (7K ± 4K)
    ³according to UL 508A, NITW File on request

  2. CS 030: 03060.0-01

    Operating voltage: 230 VAC 50/60 Hz
    Max. current (inrush): 13.0 A
    Recommended pre-fuse T (time-delay): 10.0 A
    Setting range²: none (no integrated controls)
    Approvals: UL File No. E150057³ / VDE / EAC
    ²Switching difference 12.6°F ± 7°F tolerance (7K ± 4K)
    ³according to UL 508A, NITW File on request

  3. CS 030: 03060.9-00

    Operating voltage: 120 VAC 50/60 Hz
    Max. current (inrush): 16.0 A
    Recommended pre-fuse T (time-delay): 16.0 A
    Setting range²: 32 to 140 °F
    Approvals: UL File No. E150057³ / EAC
    ²Switching difference 12.6°F ± 7°F tolerance (7K ± 4K)
    ³according to UL 508A, NITW File on request

  4. CS 030: 03060.9-01

    Operating voltage: 120 VAC 50/60 Hz
    Max. current (inrush): 16.0 A
    Recommended pre-fuse T (time-delay): 16.0 A
    Setting range²: none (no integrated controls)
    Approvals: UL File No. E150057³ / EAC
    ²Switching difference 12.6°F ± 7°F tolerance (7K ± 4K)
    ³according to UL 508A, NITW File on request